Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 133
Filtrar
1.
Am J Ophthalmol ; 261: 141-164, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38311154

RESUMEN

PURPOSE: To compare the prevalence, location and magnitude of optic nerve head (ONH) OCT-detected, exposed neural canal (ENC), externally oblique choroidal border tissue (EOCBT) and exposed scleral flange (ESF) regions in 122 highly myopic (Hi-Myo) versus 362 nonhighly myopic healthy (Non-Hi-Myo-Healthy) eyes. DESIGN: Cross-sectional study. METHODS: After OCT radial B-scan, ONH imaging, Bruch's membrane opening (BMO), the anterior scleral canal opening (ASCO), and the scleral flange opening (SFO) were manually segmented in each B-scan and projected to BMO reference plane. The direction and magnitude of BMO/ASCO offset and BMO/SFO offset as well as the location and magnitude of ENC, EOCBT and ESF regions, perineural canal (pNC) retinal nerve fiber layer thickness (RNFLT) and pNC choroidal thickness (CT) were calculated within 30° sectors relative to the Foveal-BMO (FoBMO) axis. Hi-ESF eyes were defined to be those with an ESF region ≥100 µms in at least 1 sector. RESULTS: Hi-Myo eyes more frequently demonstrated Hi-ESF regions (87/122) than Non-Hi-myo-Healthy eyes (73/362) and contained significantly larger ENC, EOCBT, and ESF regions (P < .001) which were greatest in magnitude and prevalence within the inferior-temporal FoBMO sectors where Hi-Myo pNC-RNFLT and pNCCT were thinnest. BMO/ASCO offset and the BMO/SFO offset were both significantly increased (P < .001) in the Hi-Myo eyes, with the latter demonstrating a greater increase. CONCLUSIONS: ENC region tissue remodeling that includes the scleral flange is enhanced in Hi-Myo compared to Non-Hi-Myo-Healthy eyes. Longitudinal studies are necessary to determine whether the presence of an ENC region influences ONH susceptibility to aging and/or glaucoma.


Asunto(s)
Miopía , Disco Óptico , Humanos , Disco Óptico/anatomía & histología , Tomografía de Coherencia Óptica/métodos , Tubo Neural , Estudios Transversales , Miopía/diagnóstico , Lámina Basal de la Coroides/anatomía & histología , Presión Intraocular
2.
Transl Vis Sci Technol ; 13(1): 5, 2024 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-38197730

RESUMEN

Purpose: We wanted to develop a deep-learning algorithm to automatically segment optic nerve head (ONH) and macula structures in three-dimensional (3D) wide-field optical coherence tomography (OCT) scans and to assess whether 3D ONH or macula structures (or a combination of both) provide the best diagnostic power for glaucoma. Methods: A cross-sectional comparative study was performed using 319 OCT scans of glaucoma eyes and 298 scans of nonglaucoma eyes. Scans were compensated to improve deep-tissue visibility. We developed a deep-learning algorithm to automatically label major tissue structures, trained with 270 manually annotated B-scans. The performance was assessed using the Dice coefficient (DC). A glaucoma classification algorithm (3D-CNN) was then designed using 500 OCT volumes and corresponding automatically segmented labels. This algorithm was trained and tested on three datasets: cropped scans of macular tissues, those of ONH tissues, and wide-field scans. The classification performance for each dataset was reported using the area under the curve (AUC). Results: Our segmentation algorithm achieved a DC of 0.94 ± 0.003. The classification algorithm was best able to diagnose glaucoma using wide-field scans, followed by ONH scans, and finally macula scans, with AUCs of 0.99 ± 0.01, 0.93 ± 0.06 and 0.91 ± 0.11, respectively. Conclusions: This study showed that wide-field OCT may allow for significantly improved glaucoma diagnosis over typical OCTs of the ONH or macula. Translational Relevance: This could lead to mainstream clinical adoption of 3D wide-field OCT scan technology.


Asunto(s)
Glaucoma , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagen , Inteligencia Artificial , Tomografía de Coherencia Óptica , Estudios Transversales , Glaucoma/diagnóstico por imagen
3.
Br J Ophthalmol ; 108(2): 223-231, 2024 01 29.
Artículo en Inglés | MEDLINE | ID: mdl-36627175

RESUMEN

BACKGROUND/AIMS: To use artificial intelligence (AI) to: (1) exploit biomechanical knowledge of the optic nerve head (ONH) from a relatively large population; (2) assess ONH robustness (ie, sensitivity of the ONH to changes in intraocular pressure (IOP)) from a single optical coherence tomography (OCT) volume scan of the ONH without the need for biomechanical testing and (3) identify what critical three-dimensional (3D) structural features dictate ONH robustness. METHODS: 316 subjects had their ONHs imaged with OCT before and after acute IOP elevation through ophthalmo-dynamometry. IOP-induced lamina cribrosa (LC) deformations were then mapped in 3D and used to classify ONHs. Those with an average effective LC strain superior to 4% were considered fragile, while those with a strain inferior to 4% robust. Learning from these data, we compared three AI algorithms to predict ONH robustness strictly from a baseline (undeformed) OCT volume: (1) a random forest classifier; (2) an autoencoder and (3) a dynamic graph convolutional neural network (DGCNN). The latter algorithm also allowed us to identify what critical 3D structural features make a given ONH robust. RESULTS: All three methods were able to predict ONH robustness from a single OCT volume scan alone and without the need to perform biomechanical testing. The DGCNN (area under the curve (AUC): 0.76±0.08) outperformed the autoencoder (AUC: 0.72±0.09) and the random forest classifier (AUC: 0.69±0.05). Interestingly, to assess ONH robustness, the DGCNN mainly used information from the scleral canal and the LC insertion sites. CONCLUSIONS: We propose an AI-driven approach that can assess the robustness of a given ONH solely from a single OCT volume scan of the ONH, and without the need to perform biomechanical testing. Longitudinal studies should establish whether ONH robustness could help us identify fast visual field loss progressors. PRECIS: Using geometric deep learning, we can assess optic nerve head robustness (ie, sensitivity to a change in IOP) from a standard OCT scan that might help to identify fast visual field loss progressors.


Asunto(s)
Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagen , Inteligencia Artificial , Presión Intraocular , Tonometría Ocular , Pruebas del Campo Visual , Tomografía de Coherencia Óptica
4.
Br J Ophthalmol ; 108(4): 522-529, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-37011991

RESUMEN

PURPOSE: To assess intraocular pressure (IOP)-induced and gaze-induced optic nerve head (ONH) strains in subjects with high-tension glaucoma (HTG) and normal-tension glaucoma (NTG). DESIGN: Clinic-based cross-sectional study. METHODS: The ONH from one eye of 228 subjects (114 subjects with HTG (pre-treatment IOP≥21 mm Hg) and 114 with NTG (pre-treatment IOP<21 mm Hg)) was imaged with optical coherence tomography (OCT) under the following conditions: (1) OCT primary gaze, (2) 20° adduction from OCT primary gaze, (3) 20° abduction from OCT primary gaze and (4) OCT primary gaze with acute IOP elevation (to approximately 33 mm Hg). We then performed digital volume correlation analysis to quantify IOP-induced and gaze-induced ONH tissue deformations and strains. RESULTS: Across all subjects, adduction generated high effective strain (4.4%±2.3%) in the LC tissue with no significant difference (p>0.05) with those induced by IOP elevation (4.5%±2.4%); while abduction generated significantly lower (p=0.01) effective strain (3.1%±1.9%). The lamina cribrosa (LC) of HTG subjects exhibited significantly higher effective strain than those of NTG subjects under IOP elevation (HTG: 4.6%±1.7% vs NTG: 4.1%±1.5%, p<0.05). Conversely, the LC of NTG subjects exhibited significantly higher effective strain than those of HTG subjects under adduction (NTG: 4.9%±1.9% vs HTG: 4.0%±1.4%, p<0.05). CONCLUSION: We found that NTG subjects experienced higher strains due to adduction than HTG subjects, while HTG subjects experienced higher strain due to IOP elevation than NTG subjects-and that these differences were most pronounced in the LC tissue.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Glaucoma de Baja Tensión , Disco Óptico , Humanos , Glaucoma de Ángulo Abierto/diagnóstico , Estudios Transversales , Glaucoma de Baja Tensión/diagnóstico , Presión Intraocular , Tomografía de Coherencia Óptica
5.
Invest Ophthalmol Vis Sci ; 64(13): 11, 2023 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-37796489

RESUMEN

Purpose: The purpose of this study was to isolate the structural components of the ex vivo porcine iris tissue and to determine their biomechanical properties. Methods: The porcine stroma and dilator tissues were separated, and their dimensions were assessed using optical coherence tomography (OCT). The stroma underwent flow test (n = 32) to evaluate for permeability using Darcy's Law (ΔP = 2000 Pa, A = 0.0391 mm2), and both tissues underwent stress relaxation experiments (ε = 0.5 with initial ramp of δε = 0.1) to evaluate for their viscoelastic behaviours (n = 28). Viscoelasticity was characterized by the parameters ß (half width of the Gaussian distribution), τm (mean relaxation time constant), E0 (instantaneous modulus), and E∞ (equilibrium modulus). Results: For the stroma, the hydraulic permeability was 9.49 ± 3.05 × 10-6 mm2/Pa · s, and the viscoelastic parameters were ß = 2.50 ± 1.40, and τm = 7.43 ± 4.96 s, with the 2 moduli calculated to be E0 = 14.14 ± 6.44 kPa and E∞ = 6.08 ± 2.74 kPa. For the dilator tissue, the viscoelastic parameters were ß = 2.06 ± 1.33 and τm = 1.28 ± 1.27 seconds, with the 2 moduli calculated to be E0 = 9.16 ± 3.03 kPa and E∞ = 5.54 ± 1.98 kPa. Conclusions: We have established a new protocol to evaluate the biomechanical properties of the structural layers of the iris. Overall, the stroma was permeable and exhibited smaller moduli than those of the dilator muscle. An improved characterization of iris biomechanics may form the basis to further our understanding of angle closure glaucoma.


Asunto(s)
Glaucoma de Ángulo Cerrado , Iris , Porcinos , Animales , Iris/fisiología , Fenómenos Biomecánicos/fisiología , Tomografía de Coherencia Óptica
6.
JAMA Ophthalmol ; 141(9): 882-889, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37589980

RESUMEN

Importance: The 3-dimensional (3-D) structural phenotype of glaucoma as a function of severity was thoroughly described and analyzed, enhancing understanding of its intricate pathology beyond current clinical knowledge. Objective: To describe the 3-D structural differences in both connective and neural tissues of the optic nerve head (ONH) between different glaucoma stages using traditional and artificial intelligence-driven approaches. Design, Setting, and Participants: This cross-sectional, clinic-based study recruited 541 Chinese individuals receiving standard clinical care at Singapore National Eye Centre, Singapore, and 112 White participants of a prospective observational study at Vilnius University Hospital Santaros Klinikos, Vilnius, Lithuania. The study was conducted from May 2022 to January 2023. All participants had their ONH imaged using spectral-domain optical coherence tomography and had their visual field assessed by standard automated perimetry. Main Outcomes and Measures: (1) Clinician-defined 3-D structural parameters of the ONH and (2) 3-D structural landmarks identified by geometric deep learning that differentiated ONHs among 4 groups: no glaucoma, mild glaucoma (mean deviation [MD], ≥-6.00 dB), moderate glaucoma (MD, -6.01 to -12.00 dB), and advanced glaucoma (MD, <-12.00 dB). Results: Study participants included 213 individuals without glaucoma (mean age, 63.4 years; 95% CI, 62.5-64.3 years; 126 females [59.2%]; 213 Chinese [100%] and 0 White individuals), 204 with mild glaucoma (mean age, 66.9 years; 95% CI, 66.0-67.8 years; 91 females [44.6%]; 178 Chinese [87.3%] and 26 White [12.7%] individuals), 118 with moderate glaucoma (mean age, 68.1 years; 95% CI, 66.8-69.4 years; 49 females [41.5%]; 97 Chinese [82.2%] and 21 White [17.8%] individuals), and 118 with advanced glaucoma (mean age, 68.5 years; 95% CI, 67.1-69.9 years; 43 females [36.4%]; 53 Chinese [44.9%] and 65 White [55.1%] individuals). The majority of ONH structural differences occurred in the early glaucoma stage, followed by a plateau effect in the later stages. Using a deep neural network, 3-D ONH structural differences were found to be present in both neural and connective tissues. Specifically, a mean of 57.4% (95% CI, 54.9%-59.9%, for no to mild glaucoma), 38.7% (95% CI, 36.9%-40.5%, for mild to moderate glaucoma), and 53.1 (95% CI, 50.8%-55.4%, for moderate to advanced glaucoma) of ONH landmarks that showed major structural differences were located in neural tissues with the remaining located in connective tissues. Conclusions and Relevance: This study uncovered complex 3-D structural differences of the ONH in both neural and connective tissues as a function of glaucoma severity. Future longitudinal studies should seek to establish a connection between specific 3-D ONH structural changes and fast visual field deterioration and aim to improve the early detection of patients with rapid visual field loss in routine clinical care.


Asunto(s)
Glaucoma , Disco Óptico , Femenino , Humanos , Persona de Mediana Edad , Anciano , Tomografía de Coherencia Óptica , Inteligencia Artificial , Estudios Transversales , Estudios Prospectivos , Glaucoma/diagnóstico , Progresión de la Enfermedad , Fenotipo
7.
Invest Ophthalmol Vis Sci ; 64(11): 12, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37552032

RESUMEN

Purpose: The purpose of this study was to assess optic nerve head (ONH) deformations following acute intraocular pressure (IOP) elevations and horizontal eye movements in control eyes, highly myopic (HM) eyes, HM eyes with glaucoma (HMG), and eyes with pathologic myopia (PM) alone or PM with staphyloma (PM + S). Methods: We studied 282 eyes, comprising of 99 controls (between +2.75 and -2.75 diopters), 51 HM (< -5 diopters), 35 HMG, 21 PM, and 75 PM + S eyes. For each eye, we imaged the ONH using spectral-domain optical coherence tomography (OCT) under the following conditions: (1) primary gaze, (2) 20 degrees adduction, (3) 20 degrees abduction, and (4) primary gaze with acute IOP elevation (to ∼35 mm Hg) achieved through ophthalmodynamometry. We then computed IOP- and gaze-induced ONH displacements and effective strains. Effective strains were compared across groups. Results: Under IOP elevation, we found that HM eyes exhibited significantly lower strains (3.9 ± 2.4%) than PM eyes (6.9 ± 5.0%, P < 0.001), HMG eyes (4.7 ± 1.8%, P = 0.04), and PM + S eyes (7.0 ± 5.2%, P < 0.001). Under adduction, we found that HM eyes exhibited significantly lower strains (4.8% ± 2.7%) than PM + S eyes (6.0 ± 3.1%, P = 0.02). We also found that eyes with higher axial length were associated with higher strains. Conclusions: Our study revealed that eyes with HMG experienced significantly greater strains under IOP compared to eyes with HM. Furthermore, eyes with PM + S had the highest strains on the ONH of all groups.


Asunto(s)
Glaucoma , Miopía , Disco Óptico , Humanos , Disco Óptico/patología , Glaucoma/patología , Presión Intraocular , Miopía/patología , Tonometría Ocular , Tomografía de Coherencia Óptica/métodos , Trastornos de la Visión/patología
8.
Nat Biomed Eng ; 7(8): 986-1000, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37365268

RESUMEN

In myopic eyes, pathological remodelling of collagen in the posterior sclera has mostly been observed ex vivo. Here we report the development of triple-input polarization-sensitive optical coherence tomography (OCT) for measuring posterior scleral birefringence. In guinea pigs and humans, the technique offers superior imaging sensitivities and accuracies than dual-input polarization-sensitive OCT. In 8-week-long studies with young guinea pigs, scleral birefringence was positively correlated with spherical equivalent refractive errors and predicted the onset of myopia. In a cross-sectional study involving adult individuals, scleral birefringence was associated with myopia status and negatively correlated with refractive errors. Triple-input polarization-sensitive OCT may help establish posterior scleral birefringence as a non-invasive biomarker for assessing the progression of myopia.


Asunto(s)
Miopía , Esclerótica , Adulto , Humanos , Animales , Cobayas , Esclerótica/diagnóstico por imagen , Esclerótica/patología , Birrefringencia , Estudios Transversales , Miopía/diagnóstico por imagen , Miopía/patología , Biomarcadores
9.
Biomolecules ; 13(6)2023 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-37371541

RESUMEN

Current management of glaucomatous optic neuropathy is limited to intraocular pressure control. Neuroglobin (Ngb) is an endogenous neuroprotectant expressed in neurons and astrocytes. We recently showed that exogenous intravitreal Ngb reduced inflammatory cytokines and microglial activation in a rodent model of hypoxia. We thus hypothesised that IVT-Ngb may also be neuroprotective in experimental glaucoma (EG) by mitigating optic nerve (ON) astrogliosis and microgliosis as well as structural damage. In this study using a microbead-induced model of EG in six Cynomolgus primates, optical coherence imaging showed that Ngb-treated EG eyes had significantly less thinning of the peripapillary minimum rim width, retinal nerve fibre layer thickness, and ON head cupping than untreated EG eyes. Immunohistochemistry confirmed that ON astrocytes overexpressed Ngb following Ngb treatment. A reduction in complement 3 and cleaved-caspase 3 activated microglia and astrocytes was also noted. Our findings in higher-order primates recapitulate the effects of neuroprotection by Ngb treatment in rodent EG studies and suggest that Ngb may be a potential candidate for glaucoma neuroprotection in humans.


Asunto(s)
Glaucoma , Neuroglobina , Disco Óptico , Animales , Astrocitos , Complemento C3 , Glaucoma/tratamiento farmacológico , Microglía , Neuroglobina/administración & dosificación , Neuroglobina/uso terapéutico , Primates , Macaca fascicularis
10.
Artículo en Inglés | MEDLINE | ID: mdl-36866233

RESUMEN

Artificial intelligence (AI) has been approved for biomedical research in diverse areas from bedside clinical studies to benchtop basic scientific research. For ophthalmic research, in particular glaucoma, AI applications are rapidly growing for potential clinical translation given the vast data available and the introduction of federated learning. Conversely, AI for basic science remains limited despite its useful power in providing mechanistic insight. In this perspective, we discuss recent progress, opportunities, and challenges in the application of AI in glaucoma for scientific discoveries. Specifically, we focus on the research paradigm of reverse translation, in which clinical data are first used for patient-centered hypothesis generation followed by transitioning into basic science studies for hypothesis validation. We elaborate on several distinctive areas of research opportunities for reverse translation of AI in glaucoma including disease risk and progression prediction, pathology characterization, and sub-phenotype identification. We conclude with current challenges and future opportunities for AI research in basic science for glaucoma such as inter-species diversity, AI model generalizability and explainability, as well as AI applications using advanced ocular imaging and genomic data.

11.
Am J Ophthalmol ; 252: 225-252, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36906092

RESUMEN

PURPOSE: To use optical coherence tomography (OCT) to characterize optic nerve head (ONH) peri-neural canal (pNC) scleral bowing (pNC-SB) and pNC choroidal thickness (pNC-CT) in 69 highly myopic and 138 healthy, age-matched, control eyes. DESIGN: Cross-sectional, case control study. METHODS: Within ONH radial B-scans, Bruch membrane (BM), BM opening (BMO), anterior scleral canal opening (ASCO), and pNC scleral surface were segmented. BMO and ASCO planes and centroids were determined. pNC-SB was characterized within 30° foveal-BMO (FoBMO) sectors by 2 parameters: pNC-SB-scleral slope (pNC-SB-SS), measured within 3 pNC segments (0-300, 300-700, and 700-1000 µm from the ASCO centroid); and pNC-SB-ASCO depth relative to a pNC scleral reference plane (pNC-SB-ASCOD). pNC-CT was calculated as the minimum distance between the scleral surface and BM at 3 pNC locations (300, 700, and 1100 µm from the ASCO). RESULTS: pNC-SB increased and pNC-CT decreased with axial length (P < .0133; P < .0001) and age (P < .0211; P < .0004) among all study eyes. pNC-SB was increased (P < .001) and pNC-CT was decreased (P < .0279) in the highly myopic compared to control eyes, and these differences were greatest in the inferior quadrant sectors (P < .0002). Sectoral pNC-SB was not related to sectoral pNC-CT in control eyes, but was inversely related to sectoral pNC-CT (P < .0001) in the highly myopic eyes. CONCLUSIONS: Our data suggest that pNC-SB is increased and pNC-CT is decreased in highly myopic eyes and that these phenomena are greatest in the inferior sectors. They support the hypothesis that sectors of maximum pNC-SB may predict sectors of greatest susceptibility to aging and glaucoma in future longitudinal studies of highly myopic eyes. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.


Asunto(s)
Miopía , Disco Óptico , Humanos , Disco Óptico/anatomía & histología , Tomografía de Coherencia Óptica/métodos , Estudios Transversales , Tubo Neural , Estudios de Casos y Controles , Lámina Basal de la Coroides , Miopía/diagnóstico
12.
Int J Technol Assess Health Care ; 39(1): e11, 2023 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-36779272

RESUMEN

OBJECTIVES: To report the processes used to design and implement an assessment tool to inform funding decisions for competing health innovations in a tertiary hospital. METHODS: We designed an assessment tool for health innovation proposals with three components: "value to the institution," "novelty," and "potential for adoption and scaling." The "value to the institution" component consisted of twelve weighted value attributes identified from the host institution's annual report; weights were allocated based on a survey of the hospital's leaders. The second and third components consisted of open-ended questions on "novelty" and "barriers to implementation" to support further dialogue. Purposive literature review was performed independently by two researchers for each assessment. The assessment tool was piloted during an institutional health innovation funding cycle. RESULTS: We used 17 days to evaluate ten proposals. The completed assessments were shared with an independent group of panellists, who selected five projects for funding. Proposals with the lowest scores for "value to the institution" had less perceived impact on the patient-related value attributes of "access," "patient centeredness," "health outcomes," "prevention," and "safety." Similar innovations were reported in literature in seven proposals; potential barriers to implementation were identified in six proposals. We included a worked example to illustrate the assessment process. CONCLUSIONS: We developed an assessment tool that is aligned with local institutional priorities. Our tool can augment the decision-making process when funding health innovation projects. The tool can be adapted by others facing similar challenges of trying to choose the best health innovations to fund.


Asunto(s)
Centros Médicos Académicos , Humanos , Encuestas y Cuestionarios
13.
Transl Vis Sci Technol ; 12(2): 23, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36790820

RESUMEN

Purpose: (1) To assess the performance of geometric deep learning in diagnosing glaucoma from a single optical coherence tomography (OCT) scan of the optic nerve head and (2) to compare its performance to that obtained with a three-dimensional (3D) convolutional neural network (CNN), and with a gold-standard parameter, namely, the retinal nerve fiber layer (RNFL) thickness. Methods: Scans of the optic nerve head were acquired with OCT for 477 glaucoma and 2296 nonglaucoma subjects. All volumes were automatically segmented using deep learning to identify seven major neural and connective tissues. Each optic nerve head was then represented as a 3D point cloud with approximately 1000 points. Geometric deep learning (PointNet) was then used to provide a glaucoma diagnosis from a single 3D point cloud. The performance of our approach (reported using the area under the curve [AUC]) was compared with that obtained with a 3D CNN, and with the RNFL thickness. Results: PointNet was able to provide a robust glaucoma diagnosis solely from a 3D point cloud (AUC = 0.95 ± 0.01).The performance of PointNet was superior to that obtained with a 3D CNN (AUC = 0.87 ± 0.02 [raw OCT images] and 0.91 ± 0.02 [segmented OCT images]) and with that obtained from RNFL thickness alone (AUC = 0.80 ± 0.03). Conclusions: We provide a proof of principle for the application of geometric deep learning in glaucoma. Our technique requires significantly less information as input to perform better than a 3D CNN, and with an AUC superior to that obtained from RNFL thickness. Translational Relevance: Geometric deep learning may help us to improve and simplify diagnosis and prognosis applications in glaucoma.


Asunto(s)
Aprendizaje Profundo , Glaucoma , Disco Óptico , Humanos , Células Ganglionares de la Retina , Campos Visuales , Glaucoma/diagnóstico , Tomografía de Coherencia Óptica/métodos
14.
Am J Ophthalmol ; 250: 38-48, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36646242

RESUMEN

PURPOSE: To compare the performance of 2 relatively recent geometric deep learning techniques in diagnosing glaucoma from a single optical coherence tomographic (OCT) scan of the optic nerve head (ONH); and to identify the 3-dimensional (3D) structural features of the ONH that are critical for the diagnosis of glaucoma. DESIGN: Comparison and evaluation of deep learning diagnostic algorithms. METHODS: In this study, we included a total of 2247 nonglaucoma and 2259 glaucoma scans from 1725 participants. All participants had their ONHs imaged in 3D with Spectralis OCT. All OCT scans were automatically segmented using deep learning to identify major neural and connective tissues. Each ONH was then represented as a 3D point cloud. We used PointNet and dynamic graph convolutional neural network (DGCNN) to diagnose glaucoma from such 3D ONH point clouds and to identify the critical 3D structural features of the ONH for glaucoma diagnosis. RESULTS: Both the DGCNN (area under the curve [AUC]: 0.97±0.01) and PointNet (AUC: 0.95±0.02) were able to accurately detect glaucoma from 3D ONH point clouds. The critical points (ie, critical structural features of the ONH) formed an hourglass pattern, with most of them located within the neuroretinal rim in the inferior and superior quadrant of the ONH. CONCLUSIONS: The diagnostic accuracy of both geometric deep learning approaches was excellent. Moreover, we were able to identify the critical 3D structural features of the ONH for glaucoma diagnosis that tremendously improved the transparency and interpretability of our method. Consequently, our approach may have strong potential to be used in clinical applications for the diagnosis and prognosis of a wide range of ophthalmic disorders.


Asunto(s)
Aprendizaje Profundo , Glaucoma , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagen , Glaucoma/diagnóstico , Redes Neurales de la Computación , Tomografía de Coherencia Óptica/métodos
15.
Sci Rep ; 13(1): 558, 2023 01 11.
Artículo en Inglés | MEDLINE | ID: mdl-36631567

RESUMEN

Studies using machine learning (ML) approaches have reported high diagnostic accuracies for glaucoma detection. However, none assessed model performance across ethnicities. The aim of the study is to externally validate ML models for glaucoma detection from optical coherence tomography (OCT) data. We performed a prospective, cross-sectional study, where 514 Asians (257 glaucoma/257 controls) were enrolled to construct ML models for glaucoma detection, which was then tested on 356 Asians (183 glaucoma/173 controls) and 138 Caucasians (57 glaucoma/81 controls). We used the retinal nerve fibre layer (RNFL) thickness values produced by the compensation model, which is a multiple regression model fitted on healthy subjects that corrects the RNFL profile for anatomical factors and the original OCT data (measured) to build two classifiers, respectively. Both the ML models (area under the receiver operating [AUC] = 0.96 and accuracy = 92%) outperformed the measured data (AUC = 0.93; P < 0.001) for glaucoma detection in the Asian dataset. However, in the Caucasian dataset, the ML model trained with compensated data (AUC = 0.93 and accuracy = 84%) outperformed the ML model trained with original data (AUC = 0.83 and accuracy = 79%; P < 0.001) and measured data (AUC = 0.82; P < 0.001) for glaucoma detection. The performance with the ML model trained on measured data showed poor reproducibility across different datasets, whereas the performance of the compensated data was maintained. Care must be taken when ML models are applied to patient cohorts of different ethnicities.


Asunto(s)
Glaucoma , Células Ganglionares de la Retina , Humanos , Estudios Transversales , Reproducibilidad de los Resultados , Estudios Prospectivos , Presión Intraocular , Curva ROC , Sensibilidad y Especificidad , Glaucoma/diagnóstico , Aprendizaje Automático , Tomografía de Coherencia Óptica/métodos
16.
Ophthalmology ; 130(1): 99-110, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35964710

RESUMEN

PURPOSE: To study the associations between optic nerve head (ONH) strains under intraocular pressure (IOP) elevation with retinal sensitivity in patients with glaucoma. DESIGN: Clinic-based cross-sectional study. PARTICIPANTS: Two hundred twenty-nine patients with primary open-angle glaucoma (subdivided into 115 patients with high-tension glaucoma [HTG] and 114 patients with normal-tension glaucoma [NTG]). METHODS: For 1 eye of each patient, we imaged the ONH using spectral-domain OCT under the following conditions: (1) primary gaze and (2) primary gaze with acute IOP elevation (to approximately 35 mmHg) achieved through ophthalmodynamometry. A 3-dimensional strain-mapping algorithm was applied to quantify IOP-induced ONH tissue strain (i.e., deformation) in each ONH. Strains in the prelaminar tissue (PLT), the retina, the choroid, the sclera, and the lamina cribrosa (LC) were associated (using linear regression) with measures of retinal sensitivity from the 24-2 Humphrey visual field test (Carl Zeiss Meditec). This was performed globally, then locally according to a previously published regionalization scheme. MAIN OUTCOME MEASURES: Associations between ONH strains and values of retinal sensitivity from visual field testing. RESULTS: For patients with HTG, we found (1) significant negative linear associations between ONH strains and retinal sensitivity (P < 0.001; on average, a 1% increase in ONH strains corresponded to a decrease in retinal sensitivity of 1.1 decibels [dB]), (2) that high-strain regions colocalized with anatomically mapped regions of high visual field loss, and (3) that the strongest negative associations were observed in the superior region and in the PLT. In contrast, for patients with NTG, no significant associations between strains and retinal sensitivity were observed except in the superotemporal region of the LC. CONCLUSIONS: We found significant negative associations between IOP-induced ONH strains and retinal sensitivity in a relatively large glaucoma cohort. Specifically, patients with HTG who experienced higher ONH strains were more likely to exhibit lower retinal sensitivities. Interestingly, this trend in general was less pronounced in patients with NTG, which could suggest a distinct pathophysiologic relationship between the two glaucoma subtypes.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Glaucoma de Baja Tensión , Disco Óptico , Humanos , Pruebas del Campo Visual , Campos Visuales , Estudios Transversales , Tomografía de Coherencia Óptica/métodos , Glaucoma de Baja Tensión/diagnóstico , Presión Intraocular , Trastornos de la Visión
17.
Neurology ; 100(2): e192-e202, 2023 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-36175153

RESUMEN

BACKGROUND AND OBJECTIVES: The distinction of papilledema from other optic nerve head (ONH) lesions mimicking papilledema, such as optic disc drusen (ODD), can be difficult in clinical practice. We aimed the following: (1) to develop a deep learning algorithm to automatically identify major structures of the ONH in 3-dimensional (3D) optical coherence tomography (OCT) scans and (2) to exploit such information to robustly differentiate among ODD, papilledema, and healthy ONHs. METHODS: This was a cross-sectional comparative study of patients from 3 sites (Singapore, Denmark, and Australia) with confirmed ODD, those with papilledema due to raised intracranial pressure, and healthy controls. Raster scans of the ONH were acquired using OCT imaging and then processed to improve deep-tissue visibility. First, a deep learning algorithm was developed to identify major ONH tissues and ODD regions. The performance of our algorithm was assessed using the Dice coefficient. Second, a classification algorithm (random forest) was designed to perform 3-class classifications (1: ODD, 2: papilledema, and 3: healthy ONHs) strictly from their drusen and prelamina swelling scores (calculated from the segmentations). To assess performance, we reported the area under the receiver operating characteristic curve for each class. RESULTS: A total of 241 patients (256 imaged ONHs, including 105 ODD, 51 papilledema, and 100 healthy ONHs) were retrospectively included in this study. Using OCT images of the ONH, our segmentation algorithm was able to isolate neural and connective tissues and ODD regions/conglomerates whenever present. This was confirmed by an averaged Dice coefficient of 0.93 ± 0.03 on the test set, corresponding to good segmentation performance. Classification was achieved with high AUCs, that is, 0.99 ± 0.001 for the detection of ODD, 0.99 ± 0.005 for the detection of papilledema, and 0.98 ± 0.01 for the detection of healthy ONHs. DISCUSSION: Our artificial intelligence approach can discriminate ODD from papilledema, strictly using a single OCT scan of the ONH. Our classification performance was very good in the studied population, with the caveat that validation in a much larger population is warranted. Our approach may have the potential to establish OCT imaging as one of the mainstays of diagnostic imaging for ONH disorders in neuro-ophthalmology, in addition to fundus photography.


Asunto(s)
Drusas del Disco Óptico , Disco Óptico , Papiledema , Humanos , Disco Óptico/diagnóstico por imagen , Disco Óptico/patología , Papiledema/diagnóstico por imagen , Drusas del Disco Óptico/diagnóstico , Drusas del Disco Óptico/diagnóstico por imagen , Inteligencia Artificial , Estudios Retrospectivos , Estudios Transversales , Tomografía de Coherencia Óptica/métodos
18.
JAMA Ophthalmol ; 140(10): 974-981, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36048435

RESUMEN

Importance: Deep learning (DL) networks require large data sets for training, which can be challenging to collect clinically. Generative models could be used to generate large numbers of synthetic optical coherence tomography (OCT) images to train such DL networks for glaucoma detection. Objective: To assess whether generative models can synthesize circumpapillary optic nerve head OCT images of normal and glaucomatous eyes and determine the usability of synthetic images for training DL models for glaucoma detection. Design, Setting, and Participants: Progressively growing generative adversarial network models were trained to generate circumpapillary OCT scans. Image gradeability and authenticity were evaluated on a clinical set of 100 real and 100 synthetic images by 2 clinical experts. DL networks for glaucoma detection were trained with real or synthetic images and evaluated on independent internal and external test data sets of 140 and 300 real images, respectively. Main Outcomes and Measures: Evaluations of the clinical set between the experts were compared. Glaucoma detection performance of the DL networks was assessed using area under the curve (AUC) analysis. Class activation maps provided visualizations of the regions contributing to the respective classifications. Results: A total of 990 normal and 862 glaucomatous eyes were analyzed. Evaluations of the clinical set were similar for gradeability (expert 1: 92.0%; expert 2: 93.0%) and authenticity (expert 1: 51.8%; expert 2: 51.3%). The best-performing DL network trained on synthetic images had AUC scores of 0.97 (95% CI, 0.95-0.99) on the internal test data set and 0.90 (95% CI, 0.87-0.93) on the external test data set, compared with AUCs of 0.96 (95% CI, 0.94-0.99) on the internal test data set and 0.84 (95% CI, 0.80-0.87) on the external test data set for the network trained with real images. An increase in the AUC for the synthetic DL network was observed with the use of larger synthetic data set sizes. Class activation maps showed that the regions of the synthetic images contributing to glaucoma detection were generally similar to that of real images. Conclusions and Relevance: DL networks trained with synthetic OCT images for glaucoma detection were comparable with networks trained with real images. These results suggest potential use of generative models in the training of DL networks and as a means of data sharing across institutions without patient information confidentiality issues.


Asunto(s)
Aprendizaje Profundo , Glaucoma , Disco Óptico , Humanos , Tomografía de Coherencia Óptica/métodos , Campos Visuales , Glaucoma/diagnóstico , Disco Óptico/diagnóstico por imagen
19.
Am J Ophthalmol ; 240: 205-216, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35247336

RESUMEN

PURPOSE: To assess whether the 3-dimensional (3D) structural configuration of the central retinal vessel trunk and its branches (CRVT&B) could be used as a diagnostic marker for glaucoma. DESIGN: Retrospective, deep-learning approach diagnosis study. METHODS: We trained a deep learning network to automatically segment the CRVT&B from the B-scans of the optical coherence tomography (OCT) volume of the optic nerve head. Subsequently, 2 different approaches were used for glaucoma diagnosis using the structural configuration of the CRVT&B as extracted from the OCT volumes. In the first approach, we aimed to provide a diagnosis using only 3D convolutional neural networks and the 3D structure of the CRVT&B. For the second approach, we projected the 3D structure of the CRVT&B orthographically onto sagittal, frontal, and transverse planes to obtain 3 two-dimensional (2D) images, and then a 2D convolutional neural network was used for diagnosis. The segmentation accuracy was evaluated using the Dice coefficient, whereas the diagnostic accuracy was assessed using the area under the receiver operating characteristic curves (AUCs). The diagnostic performance of the CRVT&B was also compared with that of retinal nerve fiber layer (RNFL) thickness (calculated in the same cohorts). RESULTS: Our segmentation network was able to efficiently segment retinal blood vessels from OCT scans. On a test set, we achieved a Dice coefficient of 0.81 ± 0.07. The 3D and 2D diagnostic networks were able to differentiate glaucoma from nonglaucoma subjects with accuracies of 82.7% and 83.3%, respectively. The corresponding AUCs for the CRVT&B were 0.89 and 0.90, higher than those obtained with RNFL thickness alone (AUCs ranging from 0.74 to 0.80). CONCLUSIONS: Our work demonstrated that the diagnostic power of the CRVT&B is superior to that of a gold-standard glaucoma parameter, that is, RNFL thickness. Our work also suggested that the major retinal blood vessels form a "skeleton"-the configuration of which may be representative of major optic nerve head structural changes as typically observed with the development and progression of glaucoma.


Asunto(s)
Glaucoma , Presión Intraocular , Biomarcadores , Glaucoma/diagnóstico , Humanos , Curva ROC , Vasos Retinianos/diagnóstico por imagen , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos
20.
Invest Ophthalmol Vis Sci ; 63(2): 23, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35147659

RESUMEN

Purpose: The purpose of this study was to investigate whether the lamina cribrosa (LC) curve changes in response to intraocular pressure (IOP) reduction following administration of topical ocular hypotensive eye drops in eyes with normal tension glaucoma (NTG). Methods: Ninety-three eyes of 93 patients with treatment naïve NTG at initial examination and with ≥20% reduction from baseline IOP following administration of topical ocular hypotensive eye drops were included. Serial horizontal B-scan images of the optic nerve head (ONH) were obtained from each eye using enhanced depth imaging spectral domain optical coherence tomography (OCT) before and 1 year after IOP-lowering treatment. The LC curvature in each eye was assessed by measuring the LC curvature index (LCCI) in horizontal OCT B-scan images obtained at three (superior, central, and inferior) locations spaced equidistantly across the vertical optic disc diameter before and after IOP-lowering treatment. We evaluated the OCT detectible change in the LC curvature based on the interval change of LCCI to exceed the intersession standard deviation of 1.96 times and factors associated with the magnitude of the LCCI change in the eyes showing significant LC change. Results: IOP decreased from 15.7 ± 2.5 mm Hg at baseline to 11.2 ± 1.7 mm Hg after topical glaucoma medication. Among the 93 subjects, 62 (66.7%) eyes showed the significant reduction of the LCCI (interssetional change over 1.5) after the treatment; greater interssessional change of the LCCI after IOP reduction was associated with younger age (P = 0.020) and larger baseline LCCI (P < 0.001). Conclusions: The OCT detectible changes in LC curvature occurred in response to a modest decrease in the IOP in the naïve NTG eyes. The therapeutic benefit of these changes need to be assessed in longitudinal studies.


Asunto(s)
Presión Intraocular/fisiología , Glaucoma de Baja Tensión/fisiopatología , Hipotensión Ocular/fisiopatología , Disco Óptico/patología , Administración Oftálmica , Anciano , Antihipertensivos/uso terapéutico , Presión Sanguínea/fisiología , Femenino , Gonioscopía , Humanos , Glaucoma de Baja Tensión/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Soluciones Oftálmicas , Disco Óptico/diagnóstico por imagen , Estudios Prospectivos , Microscopía con Lámpara de Hendidura , Tomografía de Coherencia Óptica , Tonometría Ocular , Agudeza Visual/fisiología , Pruebas del Campo Visual , Campos Visuales/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...